  • curprev 22:2122:21, 22 September 2026 Josh talk contribs 12,930 bytes +4,738 Rebuild from Atari 400/800 Field Service Manual (hosted): C98-C103 'filter caps' do not exist; '+12V at 4050 pin 1' and '-5V at 4050 pin 8' are wrong (4050 runs on +5V, pin 8 is ground); the 400/800 have no OPTION-key self test. Added Atari's Section 6 symptom checklist, interlock switch S201, module-bay cooling change, Rev A/B ROM warning; cited throughout undo

21 September 2026

26 March 2026

9 August 2025

9 May 2025