The Apple Multiple Scan 720 Display volume of Apple's Service Source is a 109-page service manual. The PDF was distilled on 24 September 1997, making it one of the last CRT display volumes Apple produced.

Specifications as printed

Item Value
Picture tube 17 in diagonal flat square CRT, 16.0 in diagonal viewable; 0.28 mm dot pitch
Screen resolution from 640 x 480 at 60 Hz (VGA) upwards
Scan rates vertical refresh 48-160 Hz; horizontal 30-70 kHz
Connector 15-pin miniature D-type
Mains 100-120 VAC; 220-240 VAC, 50-60 Hz (two ranges, not a single universal supply)
Power 120 W maximum
Size / weight 17.0 in (431 mm) H x 16.2 in (412 mm) W x 16.9 in (428.5 mm) D; 37.5 lb (17 kg)

Contents

  • Hot Issues (pdf pp. 2-6) - Apple's late-added chapter of field problems, which in this volume precedes Basics.
  • Basics - Overview (pdf pp. 8-11)
  • Specifications - Characteristics, Controls and Ports, Physical and Electrical, Environmental (pdf pp. 13-26)
  • Troubleshooting - General, First Checklist, symptom charts for No Raster, Video and Geometry (pdf pp. 28-38)
  • Take Apart - Safety Guidelines, List of Tools, Tilt-Swivel Monitor Stand, Rear Housing, EMI Shield, Main Deflection Board and CRT/Video Board Module, Video Cable, Front Bezel (pdf pp. 40-76)
  • Adjustments - Introduction to the On-Screen Display, Non-User Controls (pdf pp. 78-107)
  • Exploded View (pdf pp. 108-109)

All alignment on this display is done through the on-screen display, including the non-user controls; there are no internal preset pots to reach for. That changes the shape of a geometry repair completely from the earlier Apple monitors.

Note also that the main deflection board and CRT/video board are replaced as one module - they are not separately serviceable here.

What this manual does not contain

No parts list, no schematic, no component values, no fuse rating, no high-voltage figure.

Pages that cite this document

A CRT display holds a lethal charge on the anode after the mains is removed. Follow CRT Discharge Procedure before working inside one.

Download: Multiple scan 720 display.pdf