Sinclair ZX Spectrum 128 Capacitor Replacement Guide

This guide covers the capacitors on the Sinclair ZX Spectrum 128. Sinclair published a full component-level parts list for the 128, so unlike the Amstrad-built +2 every capacitor's designator, value, rating and type is documented — the tables below are transcribed from Table 5.2 (main PCB) and Table 5.3 (keypad PCB) of the Service Manual.[1]
⚠️ Safety and board handling
[edit | edit source]There are no mains voltages inside the computer — it runs from an external supply and the highest rail on the board is +12 V, so capacitor work here is low voltage.[1]
The board still needs care. Use recognised desoldering technique and an earthed, low-power iron; add fresh flux and solder to old joints before removing anything, keep dwell times short, and inspect for solder splatter afterwards — hairline bridges can measure several ohms and cause very misleading faults.[1]
Pay particular attention to the area around the heatsink fixings, where hairline cracks in the board are a documented cause of intermittent faults on Spectrums.[2]
Is the 128 a recap candidate?
[edit | edit source]The 128 uses ordinary leaded electrolytics and is not a machine with a systematic capacitor plague — it is not a "recap on sight" case. There are, however, only 13 electrolytics on the whole main board, so a targeted recap is quick and cheap when it is justified.
Recap when there is evidence:
- Visibly failed parts — bulging, leaking, crusty residue or a cracked sleeve.
- Supply instability — random crashes, or rails out of tolerance or showing ripple. The parts to look at are C25, C44/C45 (supply smoothing) and C111/C112 (the −12 V charge pump).
- Dead RS-232 or keypad — check C111/C112 in the −12 V charge pump, since both ports depend on that rail.[1]
- Wavy lines across the display — press each electrolytic in turn; if the artefact clears while pressing one, that is the culprit.[2]
Do not recap to cure jailbars. Vertical banding on the RGB output is a noise artefact that survives a routine recap; it has its own specific modification, described below.
Main board capacitors
[edit | edit source]From Table 5.2 of the Service Manual. Unless otherwise stated all capacitors are axial types. Designators not listed here are marked "not used" in the parts list — the 128 board has many unpopulated positions.[1]
Electrolytics — the recap targets
[edit | edit source]| Ref | Value | Rating / tolerance | Notes |
|---|---|---|---|
| C25 | 100 µF | 10 V, −10% +80% | Supply smoothing |
| C27 | 1 µF | 50 V, 10% | |
| C28 | 22 µF | 10 V, −10% +80% | Right of the 5-way keyboard connector. Changed to 47 µF in the jailbars modification |
| C34 | 22 µF | 10 V, −10% +80% | |
| C44, C45 | 100 µF | 10 V, −10% +80% | C44 smooths the +12 V rail with D15 |
| C50 | 22 µF | 10 V, −10% +80% | |
| C74 | 4.7 µF | 5 V minimum | |
| C80 | 22 µF | 10 V, −10% +80% | |
| C111, C112 | 47 µF | 16 V, −10% +80% | The −12 V charge pump, with D28/D29. Feeds the MC1488 RS-232 driver and the keypad |
| C123 | 1 µF | 10 V, −10% +80% | |
| C127 | 1 µF | 10 V, −10% +80% |
Ceramics — normally left alone
[edit | edit source]| Ref | Value | Rating / tolerance |
|---|---|---|
| C1–C8 | 22 nF | 25 V, 10% |
| C26 | 22 nF | 25 V, 10% |
| C29, C30 | 22 nF | 25 V, 10% |
| C31, C32 | 100 nF | 25 V, 10% |
| C35 | 10 nF | 25 V, 10% |
| C41 | 22 nF | 25 V, 10% |
| C43 | 100 nF | 25 V, 10% |
| C49 | 560 pF | 25 V, 10% |
| C55–C62 | 22 nF | 25 V, 10% |
| C66 | 22 nF | 25 V, 10% |
| C67 | 100 pF | 25 V, 10% |
| C75 | 100 nF | 25 V, 10% |
| C100 | 10 nF | 25 V, 10% |
| C101 | 22 nF | 25 V, 10% |
| C104 | 100 nF | 25 V, 10% |
| C105 | 150 pF | 25 V, 10% |
| C106–C110 | 22 nF | 25 V, 10% |
| C113, C114 | 47 nF | 25 V, 10% |
| C115 | 330 pF | 25 V, 2% |
| C116 | 10 nF | 25 V, 10% |
| C118, C119 | 1 nF | 25 V, 10% |
| C120 | 100 pF | 25 V, 10% |
| C121 | 47 pF | 25 V, 10% |
| C122 | 1 nF | 25 V, 10% |
| C124 | 20 pF | 25 V, 2% — see note below |
| C125 | 100 nF | 25 V, 10% |
| C126 | 22 pF | 25 V, 10% |
| C128 | 47 nF | 25 V, 10% |
| C129 | 100 pF | 25 V, 10% |
| C130 | See note | 25 V, 2% |
Note on C124 and C130. The Service Manual states that if preferred, the 20 pF capacitor used for C124 may be split into two parallel capacitors of 10 pF ±2% fitted at positions C124 and C130. That is why C130's value is given by reference rather than as a number — whether it is populated depends on which option the board was built with. Check your own board.[1]
The manual also notes that provision was made on the PCB for a 2–22 pF film dielectric trimmer should the need arise.[1]
The tight-tolerance parts (C115, C124, C130 at 2%) sit in timing and colour circuitry — if you replace them, match the tolerance, not just the value.
Keypad PCB capacitors
[edit | edit source]The numeric keypad has its own small board carrying a General Instrument PIC1652 microcontroller:[1]
| Ref | Value | Rating / tolerance | Type |
|---|---|---|---|
| C1 | 1 µF | 10 V, −10% +80% | Electrolytic |
| C2, C3 | 47 pF | 25 V, 10% | Ceramic |
The jailbars modification
[edit | edit source]Faint vertical banding on plain, light-coloured areas, visible on the RGB output but not over RF or composite, is a well-known Toastrack characteristic. It is a noise and ground-plane artefact, so an ordinary recap does not cure it. The established modification is:[3]
- Replace C28 with a 47 µF axial electrolytic in place of the original 22 µF. C28 sits to the right of the 5-way keyboard connector.
- Replace C7 and C8 with 1 µF ceramic capacitors in place of the original 22 nF parts. These sit next to the IC12 and IC13 RAM devices at the bottom left of the board.
This significantly reduces the banding without eliminating it entirely. On the 48K machines the equivalent change is C5–C8 to 150–220 nF; on a grey +2 it is C52.[3]
Choosing replacements
[edit | edit source]- Use 105 °C aluminium electrolytics of equal capacitance and equal-or-higher voltage. The originals are 10 V and 16 V parts; modern 16 V or 25 V equivalents are fine.
- Note the wide original tolerances (−10% +80% on most electrolytics) — modern ±20% parts are comfortably within specification.
- Most originals are axial. Axial parts remain available; if fitting radial replacements, form and insulate the leads neatly so nothing shorts to adjacent tracks.
- Match the tolerance on the 2% parts (C115, C124, C130).
- The ceramics are stable and are not normally replaced — except deliberately, as part of the jailbars modification.
Replacement procedure
[edit | edit source]- Unplug the power, open the case and disconnect both keyboard tails carefully.
- Lift the board out so it is supported flat.
- Record the value, voltage and polarity of each electrolytic before removing it, cross-checking against the table above and the circuit diagrams.
- Add fresh flux and solder to both joints and let it mix with the old solder.
- Lift one lead at a time with the joint fully molten, then clear the hole with wick.
- Fit the replacement the correct way round; solder and trim.
- Inspect for bridges and splatter before reassembly.
Post-recap verification
[edit | edit source]- Power up — ideally on a current-limited supply — and confirm the 128 menu appears.
- Check the rails: +5 V, +12 V, −12 V and −5 V. A missing −12 V rail will show up as a dead RS-232 port and dead keypad.
- Verify the clocks are clean and jitter-free: 17.734475 MHz at IC37 pin 6, 3.54689 MHz at IC2 pin 6, and 8.8 MHz at IC1 pins 46/47.[1]
- Check the display for wavy lines or new artefacts.
- Test AY sound (via
PLAY) and the beeper (viaBEEP), a tape load, and the full keyboard.
If a previously-working function fails after the recap, check the polarity of every replaced electrolytic first.
Related pages
[edit | edit source]- Sinclair ZX Spectrum 128
- Sinclair ZX Spectrum 128 General Maintenance
- Sinclair ZX Spectrum 128 Troubleshooting Guide
- Sinclair ZX Spectrum+ Capacitor Replacement Guide — the 48K machine
- Sinclair ZX Spectrum +2 Capacitor Replacement Guide — the Amstrad repackaging, which has no published parts list
- Capacitor Failure Symptoms
References
[edit | edit source]- ↑ 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 ZX Spectrum 128 Service Manual, Sinclair Research Ltd, Table 5.2 (Main PCB Components), Table 5.3 (Keypad PCB Components) and the accompanying notes; also the power supply description and repair notes.
- ↑ 2.0 2.1 Worsley, Ian. Repairing Spectrum & Spectrum Plus, Lil Old Sinclair Technical Information Repository. Source for the hairline-crack warning, the wavy-lines capacitor test and general Spectrum repair practice.
- ↑ 3.0 3.1 "Fixing Vertical 'Jailbars' on your 48K, 128K and Grey Spectrum +2", Spectrum for Everyone.