Application Guidelines for Aluminum Electrolytic Capacitors - Technical Notes CAT.8101H (Nichicon Corporation), prepared in accordance with JEITA/EIAJ RCR-2367D.

Manufacturer reference for aluminium electrolytic capacitors. Cited on this wiki for what actually comes out of a venting capacitor (vaporised hydrogen and electrolyte at over 100 degrees C, not combustion smoke), the first-aid guidance (flush eyes with water; wash skin with soap and water), the instruction that capacitors must not be exposed to acidic or alkaline solutions, the recommended storage conditions (5-35 degrees C, 75 per cent RH or less), the requirement to discharge a capacitor before removing it, and the defined failure modes (short, open, capacitance drop / high ESR, and pressure-relief vent operation).

Note that Nichicon publishes no pH figure for the electrolyte and recommends washing rather than neutralising - which is why this wiki no longer tells readers to neutralise capacitor residue with an alkali.

Source

[edit | edit source]

Nichicon Corporation technical literature, nichicon.co.jp/english/products/pdf/aluminum.pdf.

Licensing

[edit | edit source]

Copyright Nichicon Corporation. Freely distributed manufacturer application literature, hosted here for reference. Not under a free licence.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeDimensionsUserComment
current01:31, 23 September 20260 ร— 0 (3.97 MB)Josh (talk | contribs)Nichicon application guidelines - manufacturer source for electrolytic capacitor venting, handling and failure modes