Super Nintendo Troubleshooting Guide: Difference between revisions
No edit summary ย |
|||
| Line 20: | Line 20: | ||
''Note: This guide does '''not''' cover Super Famicom Box, Satellaview, or SNES CD add-ons.'' | ''Note: This guide does '''not''' cover Super Famicom Box, Satellaview, or SNES CD add-ons.'' | ||
== | == Diagnostic Tools & Techniques == | ||
=== Visual Inspection === | === Visual Inspection === | ||
| Line 47: | Line 47: | ||
* For surface-mount chips, use a donor board or hot-air rework for replacement. | * For surface-mount chips, use a donor board or hot-air rework for replacement. | ||
== | == Common Symptoms & Solutions == | ||
{| class="wikitable styledtable" | {| class="wikitable styledtable" | ||
| Line 86: | Line 86: | ||
|} | |} | ||
== | == Notes on Major Components == | ||
* '''CPU (5A22)''': Handles main processing; failure causes no-boot or erratic behaviour. | * '''CPU (5A22)''': Handles main processing; failure causes no-boot or erratic behaviour. | ||
| Line 96: | Line 96: | ||
* '''Voltage Regulator''': Converts input to +5 V (and +12 V on some boards); failure causes power issues. | * '''Voltage Regulator''': Converts input to +5 V (and +12 V on some boards); failure causes power issues. | ||
== | == Test Points & Voltages == | ||
{| class="wikitable styledtable" | {| class="wikitable styledtable" | ||
| Line 118: | Line 118: | ||
|} | |} | ||
== | == Warnings == | ||
* Always power off and unplug before working inside the SNES. | * Always power off and unplug before working inside the SNES. | ||