The IBM 5151, which IBM called simply the IBM Monochrome Display, is the green-phosphor TTL monitor sold with the original IBM PC (5150) when it was ordered with the IBM Monochrome Display Adapter (MDA). It displays 80 × 25 text only — it has no graphics capability — but the MDA's large 9 × 14 character box gives an image of 720 by 350 addressable dots, which is why MDA text is visibly sharper than CGA text.

IBM Monochrome Display
IBM monitors, left to right: 5151 monochrome, 5153 colour, 5154 Enhanced Color Display
Manufacturer IBM
Type TTL monochrome CRT monitor
Release date 1981 (with the original IBM PC)
Interface TTL digital, 9-pin D-shell (driven by the IBM Monochrome Display Adapter)
Compatible IBM PC (5150), IBM PC XT (5160), IBM PC AT (5170), MDA-compatible systems
Dimensions 280 mm H × 380 mm L × 350 mm D
Weight 7.9 kg (17.3 lb)
Model 5151

Display Characteristics

IBM's own figures:[1]

  • CRT: 28.3 cm (11.5 in) diagonal, 90° deflection.
  • Phosphor: P39, high persistence, green. Long persistence suppresses flicker at the 5151's low refresh rate, at the cost of smearing on moving content.
  • Screen surface: etched to reduce glare.
  • Presentation: 80 characters wide by 25 rows deep, each character defined in a 14 PEL high by 9 PEL wide matrix.
  • Vertical drive: screen refreshed at 50 Hz, with 350 lines of vertical resolution and 720 lines of horizontal resolution.
  • Horizontal drive: positive-level, TTL-compatible, at 18.432 kHz.
  • Video bandwidth: 16.257 MHz maximum at −3 dB.
  • Heat output: 325 BTU/hr. Power cable 0.914 m, signal cable 1.22 m.

Measured at the adapter, MDA horizontal sync is an 8 µs positive-going pulse every 54.3 µs and vertical sync is an 850 µs negative-going pulse every 20 ms.[2]

The 5151 will not work with a CGA card: CGA scans horizontally at 15.75 kHz, well outside the 5151's fixed 18.432 kHz.[2]

Power

The 5151 has no mains cord of its own. It takes both signal and power from the system unit: the signal cable comes from the display adapter, and a second cable takes ac power from a non-standard switched socket on the rear of the PC's power supply, so the system unit's power switch controls the display.[1] That outlet supplies a maximum of 0.75 A and IBM states it is intended only for this display.[3]

Two models were built, a 110 Vac model and a 220/240 Vac model, and IBM's Options and Adapters section carries a separate full schematic for each.[1]

Input Connector

A 9-pin D-shell at standard TTL levels — 0.0 to 0.6 Vdc at down level, +2.4 to 3.5 Vdc at up level.[4]

MDA / 5151 9-pin connector
Pin Signal
1 Ground
2 Ground
3, 4, 5 Not used
6 + Intensity
7 + Video
8 + Horizontal sync
9 − Vertical sync

Pins 3, 4 and 5 being physically absent from the plug is normal, not damage — they are unused in the MDA standard.[5]

The display's three brightness levels (off, normal, bright) come from the combination of the Video and Intensity lines, not from an analogue video level.[4]

Common Faults

  • Stiff brightness and contrast knobs. Known behaviour on a healthy 5151, and probably deliberate. Not a fault.[5]
  • Stable raster with the brightness turned up, but no characters. On a 5151 specifically, a stable raster proves the monitor is receiving correct horizontal and vertical sync from the MDA card. Work through: contrast set too low; a faulty MDA card generating sync but no video; an open video wire in the cable; a poor connection on pin 7 at the plug; then the video path inside the monitor. IC201, an SN7406A, has been reported failed by more than one owner.[5]
  • No display at all, not even a raster. The 5151 needs an incoming horizontal sync signal from a working, initialised MDA card to produce any raster at all. Before condemning the monitor, check that the card is present, seated and initialised — motherboard switch settings that select EGA instead of MDA leave it uninitialised.[5]
  • Full or partial vertical collapse. A known symptom, with circuit diagrams and expected waveforms published for the vertical deflection stage.[5]
  • Bright spot or line when switching off. Known behaviour, not a fault.[5]
  • Dim or shrunken raster, or geometry that drifts as the set warms up. Points at ageing electrolytics on the analogue board. See Capacitor Failure Symptoms.

A self-inflicted fault worth knowing about

Because of the way the 5151 is designed, an improper horizontal sync signal can damage it — and software alone is enough to produce that situation, by reprogramming the 6845 on the MDA card outside MDA timings.[5] Do not run 6845 timing experiments or untested display software against a 5151 you care about.

CRT Safety

The 5151's CRT retains a lethal anode charge after the set is switched off and unplugged, and its mains-derived circuitry sits at line potential while it is running. Discharge the tube before working inside it — see CRT Discharge Procedure.

References

  1. ↑ 1.0 1.1 1.2 IBM, IBM Monochrome Display, Options and Adapters section, Personal Computer Hardware Reference Library — hosted on this wiki as File:IBM Options and Adapters - IBM Monochrome Display (5151).pdf. "Description" and "Specifications": the two-cable arrangement with power taken from the system unit, the 28.3 cm (11.5 in) diagonal 90-degree-deflection CRT, P39 high-persistence green phosphor with an etched anti-glare surface, 80 characters by 25 rows in a 14 PEL high by 9 PEL wide matrix, maximum video bandwidth 16.257 MHz at −3 dB, 50 Hz vertical refresh with 350 lines vertical and 720 lines horizontal resolution, positive-level TTL horizontal drive at 18.432 kHz, and the physical specifications quoted here. Also documented here as IBM Options and Adapters - IBM Monochrome Display.
  2. ↑ 2.0 2.1 IBM: MDA / CGA / EGA, minuszerodegrees.net. Source for the side-by-side 9-pin assignments and for the measured sync pulse shapes: MDA, an 8 us positive-going horizontal pulse every 54.3 us and an 850 us negative-going vertical pulse every 20 ms; CGA, a 4 us positive-going horizontal pulse every 63.7 us and a 190 us positive-going vertical pulse every 16.7 ms.
  3. ↑ IBM, IBM 5150 Technical Reference — hosted on this wiki as File:IBM PC 5150 Technical Reference.pdf and documented as IBM PC 5150 Technical Reference. Section 1 "System Board" for the ROM and RAM subsystems; Section 3 "Power Supply", pages 3-3 to 3-6, for the 63.5 W continuous rating, the four dc outputs and their load and regulation figures, the −5 V dynamic-memory bias role, the switched 0.75 A ac outlet provided only for the IBM Monochrome Display, the overvoltage and overcurrent behaviour, the five-second minimum off time and the under- and over-voltage sense levels; Section 4 "Keyboard" for the capacitive keyboard, its Intel 8048, the permanently attached coiled five-wire cable, the 83-key layout, the scan-code protocol and the keyboard's own power-on self test.
  4. ↑ 4.0 4.1 IBM, IBM Monochrome Display and Printer Adapter, Options and Adapters section, Personal Computer Hardware Reference Library — hosted on this wiki as File:IBM Options and Adapters - IBM Monochrome Display and Printer Adapter.pdf. Source for the Motorola 6845 CRT controller, the 4 KB display buffer with no parity, the two-bytes-in-553 ns fetch giving 1.8 MB/s, the 8 KB character generator holding 256 codes, the 9 PEL by 14 PEL character box carrying a 7 PEL by 9 PEL character, the 18 kHz monitor requirement, the statement that the adapter does not support a light pen with a P39-phosphor display, the register map, the 9-pin connector pin assignments and TTL signal levels, and the printer-adapter half with its 12 latched outputs and 5 steady-state inputs. Also documented here as IBM Options and Adapters - IBM Monochrome Display and Printer Adapter.
  5. ↑ 5.0 5.1 5.2 5.3 5.4 5.5 5.6 IBM 5151 — Known Problems/Issues, minuszerodegrees.net. Source for the stiff brightness and contrast controls being normal, the raster-but-no-video diagnosis, the reported IC201 (SN7406A) failures, the vertical collapse and switch-off bright line notes, the statement that pins 3, 4 and 5 are absent from the connector by design, and the warning that an improper horizontal sync signal can damage the 5151.