Jump to content

Related changes

Enter a page name to see changes on pages linked to or from that page. (To see members of a category, enter Category:Name of category). Changes to pages on your Watchlist are in bold.

Recent changes optionsShow last 50 | 100 | 250 | 500 changes in last 1 | 3 | 7 | 14 | 30 days
Hide registered users | Hide anonymous users | Hide my edits | Show bots | Hide minor edits
Show new changes starting from 15:09, 23 September 2026
 
Page name:
List of abbreviations:
N
This edit created a new page (also see list of new pages)
m
This is a minor edit
b
This edit was performed by a bot
(±123)
The page size changed by this number of bytes

23 September 2026

     02:27  Retrobrite 3 changes history +5,445 [Josh (3×)]
     
02:27 (cur | prev) −29 Josh talk contribs (Fix the 6 per cent row of the hazard table: at 6 per cent the classification is Eye Irrit. 2 (H319), not Eye Dam. 1, which applies from 8 per cent)
     
02:15 (cur | prev) −103 Josh talk contribs (Remove self-referential wording per house rule)
     
02:09 (cur | prev) +5,577 Josh talk contribs (Rewrite with citations: deleted the unsourced 9-row treatment-duration/effectiveness table (no published study of durations exists); corrected the mechanism claim (published literature attributes ABS photodiscolouration to photo-oxidation of the polymer, not solely to brominated flame retardants); added GB/EU CLP hazard classification by concentration (H318 serious eye damage from 8 percent, so 12 percent salon developer is not merely an irritant) and the 12 percent cosmetics ceiling; added t...)
     02:15  Capacitor Failure Symptoms 2 changes history +12,684 [Josh (2×)]
     
02:15 (cur | prev) −40 Josh talk contribs (Remove self-referential wording per house rule)
     
02:07 (cur | prev) +12,724 Josh talk contribs (Rewrite with full citations (Nichicon CAT.8101H hosted here, Vishay 40110, KEMET F3011): corrected 60 Hz hum to twice mains frequency, corrected bulging mechanism to Nichicon gas generation, added missing film/X2 suppression section, added tantalum derating 60-50 percent, added Class II ceramic DC-bias behaviour, replaced Japanese-brand rule with no-datasheet-no-purchase, replaced IPA-only cleanup with Nichicon soap-and-water plus never acidic/alkaline, replaced reforming folklore with Nichic...)
     02:15  CRT Discharge Procedure 2 changes history +11,081 [Josh (2×)]
     
02:15 (cur | prev) −45 Josh talk contribs (Remove self-referential wording per house rule)
     
02:05 (cur | prev) +11,126 Josh talk contribs (Rewrite against Apple Service Guide 1990 and Goldwasser CRT notes: corrected earth-return point (ground lug, never logic board), added never-wear-a-wrist-strap rule and implosion/goggles hazard, replaced unsourced 25 kV blanket with sourced per-class figures, replaced dead-short tool with resistive tooling, removed invented 30-min wait / 10-s hold / 10-15-min re-discharge interval, added ongoing shorting lead and aquadag mechanism; full ref citations)
     01:36  Battery Explosion, Capacitor or Corrosion Damage diffhist +12,961 Josh talk contribs (Verification drive: corrected chemistry (Li-SOCl2 half-AA neutralised with bicarbonate not IPA/water; capacitor electrolyte washed not neutralised - no published pH); added cadmium hazard for NiCd; added damaged-cell handling section incl. accurate lithium fire guidance; fixed +5V range 4.75-5.25 V; corrected United Chemi-Con/Nippon Chemi-Con and OS-CON/Panasonic; removed arbitrary '100 ohm' rail threshold and Kapton '400C' claim; added IEC 60086-1 cell designations; all figures now <ref>-cit...)

21 September 2026

     21:50  Battery Explosion, Capacitor or Corrosion Damage diffhist +20 Josh talk contribs (Verification drive: flag unverified component data pending check against a primary source)

19 September 2026