Created page with "thumb|376x376px|Commodore PET 4032 with top panel lifted. Proper maintenance of the '''Commodore PET 4000 Series''' is essential to preserve functionality and prevent age-related failures. This guide covers cleaning, keyboard servicing, capacitor replacement, power supply care, and CRT-specific issues unique to these systems. == ๐Ÿงผ Regular Cleaning == The PET 4000 Series features a hinged metal chassis for easy internal acce..."
ย 
Replace the generic copied PSU/CRT text with Commodore's own drawing data: the +5 V regulator is an LM323 not a 7805, there are three regulators on the logic board and none in the supply chassis, the -5 V rail is real on this machine (unlike the PET 2001), C1 is 23,000 uF, F1 is 1.6 A slow-blow; remove the unsupported RIFA X2 instruction and the unsourced 6.3 VAC filament figure; add Commodore's electrolytic list
ย 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[File:Commodore PET 4032 Open Case.jpg|thumb|376x376px|Commodore PET 4032 with top panel lifted.]]
<templatestyles src="Template:StyledTable/styles.css" />
[[File:Commodore PET 4000 Open.jpg|thumb|440x440px|Commodore PET 4032 with the top panel lifted.]]


Proper maintenance of the '''Commodore PET 4000 Series''' is essential to preserve functionality and prevent age-related failures. This guide covers cleaning, keyboard servicing, capacitor replacement, power supply care, and CRT-specific issues unique to these systems.
This page covers routine care of the '''[[Commodore PET 4000 Series]]''': cleaning, supply checks, keyboard servicing, socket work and the CRT hazards. For fault-finding see [[Commodore PET 4000 Series Troubleshooting Guide]].


== ๐Ÿงผ Regular Cleaning ==
'''Every electrical figure here is read off Commodore's own drawings''' in the ''PET 4000 Series Technical Manual'', P/N 990438, hosted on this wiki.<ref name="tm4k">Commodore Business Machines, ''PET 4000 Series Technical Manual'', P/N 990438, for models 4016 and 4032, hosted at [[Commodore PET 4000 Series Technical Manual]]. Drawing '''8032090 Rev H, "PCB ASSY โ€“ UNIV. DYNAMIC PET"''': sheet 3 gives the board capacitors by reference designator and Commodore part number (C1/C16/C17/C23/C24 10 ยตF 25 V low-leakage 900109-03; C2 4700 ยตF 16 V 900100-44; C5 4700 ยตF 25 V 900100-45; C7/C11 47 ยตF 16 V 900101-37; C6/C51 1 ยตF 35 V tantalum 900402-13; C3/C4 0.022 ยตF ceramic; C52/C60/C61 0.01 ยตF ceramic; C74โ€“C86 and C88 47 pF ceramic; C92 220 pF ceramic; C97 82 pF dipped mica) together with transistors Q1 and Q2 (TIP29) and the piezo-acoustic transducer MT1; sheet 4 gives the diodes CR1/CR5/CR7 (1N4005), bridges CR2 and CR4 (4 A/50 V), CR3 (1N5402), the three voltage regulators โ€” '''VR1 a 7905 at โˆ’5 V/1.5 A''' (901527-03), '''VR2 a 7812 at +12 V/1 A''' (901528-04) and '''VR4 an LM323''' in TO-3 (901528-01) โ€” the 7.5 V zeners VR5 and VR6, the '''16 MHz crystal Y1''' (900556-02), the socket and header list, the 2.2 ยตH inductors L1 and L2, and the heatsinks. Drawing '''8032051 Rev E, "Power Supply Assy, 8032"''': the supply chassis is transformer T1 (320902-01) on universal power chassis 8032043-02, filter capacitor C1 of '''23,000 ยตF''' (900102-01), the dynamic PET power harness 320289-01, fuse F1 at '''125 V slow-blow 1.6 A''' (903557-04), fuse holder XF1 and rocker switch SW1 โ€” with no voltage regulator and no mains-rated suppression capacitor listed. Drawings 321450 onward cover the 12-inch and 9-inch CRT displays.</ref> Where Commodore gives no figure, none is given here.


The PET 4000 Series features a hinged metal chassis for easy internal access. Dust buildup and oxidized contacts are common in these systems.
'''This is the "universal dynamic PET" board, not the static board of the [[Commodore PET 2001]].''' The rails differ, the regulators differ and the crystal differs. Do not carry figures between the two pages in either direction.


=== Internal Cleaning ===
== Before you start ==
* Disconnect the PET from mains power.
* Carefully lift the PET's top panel to access the motherboard and CRT.
* Use compressed air and an anti-static brush to clean:
** The motherboard (especially under ROM/RAM sockets)
** Power supply area
** CRT yoke and anode cup region
** Cassette deck area (if present)
* Use '''isopropyl alcohol (>90%)''' and cotton swabs to clean stubborn areas, but avoid soaking.


=== External Case and CRT ===
* '''Mains voltage is on the primary side of T1''' whenever the machine is plugged in.
* Wipe the painted metal case with a mild soap solution on a damp microfiber cloth.
* '''C1 in the supply chassis is 23,000 ยตF.'''<ref name="tm4k" /> That is a large amount of stored energy for a low-voltage rail. Bleed it through a resistor; do not short it with a screwdriver.
* CRT screen can be cleaned using a lint-free cloth and glass cleaner sprayed onto the cloth.
* '''The CRT holds its anode charge long after power-off.''' Discharge it before working near the tube โ€” see [[CRT Discharge Procedure]].
* Avoid aggressive rubbing of the screen label ("Commodore") which may degrade over time.


== ๐Ÿ”‹ Power Supply Maintenance ==
== Regular cleaning ==


The PET 4000 Series uses an unregulated linear power supply. While robust, they require inspection:
=== Internal ===
* Disconnect from the mains and discharge the CRT before the top goes up.
* The hinged chassis lifts to expose the logic board and the display.
* Compressed air and an anti-static brush on the logic board, particularly under and around the ROM and RAM sockets, on the regulator heatsinks and around the CRT neck board.
* Isopropyl alcohol (>90 %) on swabs for stubborn areas. Do not soak.


=== Inspection Checklist ===
=== External ===
* Check transformer and rectifier board for heat stress and corrosion.
* Mild soap on a damp microfibre cloth for the painted steel case.
* Examine all '''RIFA X2 safety capacitors''' โ€” these are known to fail with age. Replace immediately if original.
* Glass cleaner sprayed onto a lint-free cloth, never onto the tube.
* Check solder joints around bridge rectifier and voltage regulators (7812, 7805, etc).
* Do not rub the screen-surround legend; the print is fragile.
* Confirm voltages at the edge connector:
** +5V, -5V, and +12V should be within 5% tolerance.


== ๐Ÿ’ฃ Capacitor Replacement (Recapping) ==
== Power supply ==


Like many vintage electronics, the PET contains aging electrolytic capacitors.
{| class="wikitable styled-table" style="width:95%; text-align:left;"
|+'''What is where'''
! Assembly !! Contents !! Regulators
|-
| Supply chassis (drawing 8032051) || Transformer T1, 23,000 ยตF filter C1, fuse F1 (1.6 A slow-blow, 125 V), rocker switch SW1 || '''None'''
|-
| Logic board (drawing 8032090) || Bridges CR2/CR4, diodes CR1/CR5/CR7, zeners VR5/VR6 || '''VR1, VR2, VR4'''
|}


=== Symptoms of Failing Capacitors ===
{| class="wikitable styled-table" style="width:95%; text-align:left;"
* Vertical hold issues on CRT
|+'''Regulators and rails'''
* Unstable startup or flickering screen
! Ref !! Device !! Rail !! Commodore part no.
* Noise in cassette audio playback/record
|-
| '''VR4''' || '''LM323''', TO-3 || +5 V || 901528-01
|-
| '''VR2''' || 7812 || +12 V, 1 A || 901528-04
|-
| '''VR1''' || 7905 || '''โˆ’5 V''', 1.5 A || 901527-03
|}
ย 
'''The +5 V regulator is an LM323, not a 7805.''' It is a TO-3 5 A part, the same one Commodore used on the early [[Commodore VIC-20]] board, and a 1 A TO-220 device is not a substitute for it.
ย 
'''There is a โˆ’5 V rail on this machine''', from VR1. The PET 2001 has none, so rail lists do not transfer between the two.
ย 
=== What to inspect ===
ย 
* Transformer and the rectifier area for heat stress, discoloured board and corrosion.
* Solder joints at VR1, VR2 and VR4 and at bridges CR2 and CR4. These are thermally cycled, heavy-current joints and a cracked one produces an intermittent that mimics a failing chip.
* The regulator heatsinks and the thermal compound under them. Commodore fits heatsinks and thermal compound to this board because these parts run hot.<ref name="tm4k" />
* '''Commodore's supply-chassis drawing names no mains-rated X-class or Y-class suppression capacitor''' โ€” the chassis holds one capacitor, C1, and it is the 23,000 ยตF filter on the low-voltage side.<ref name="tm4k" /> The "replace the RIFAs on sight" advice that applies to many European machines of this era is not supported by Commodore's documentation for this one. If your machine has such a part fitted, deal with it on its merits; do not go hunting for one on the strength of a generic warning.
ย 
=== Voltage test points ===
ย 
{| class="wikitable styled-table" style="width:90%; text-align:left;"
|+'''Where to measure'''
! Rail !! Where !! Note
|-
| '''+5 V''' || VR4 output, or '''6502 pin 8''' || Pins 1 and 21 are ground; '''pin 40 is RESET''', not a supply pin
|-
| '''+12 V''' || VR2 output || 1 A device
|-
| '''โˆ’5 V''' || VR1 output || 1.5 A device. Dynamic RAM of this generation needs it
|-
| Unregulated || Across C1 in the supply chassis || 23,000 ยตF. Treat with respect
|}
ย 
A rail more than a few per cent off its nominal means the regulator, its heatsinking or the filtering ahead of it. Commodore publishes no tolerance band of its own for these rails, so none is quoted here; work to the regulators' own datasheet figures.
ย 
== Capacitors ==
ย 
Commodore's list for the logic board. This is the whole electrolytic complement.<ref name="tm4k" />
ย 
{| class="wikitable styled-table" style="width:100%; text-align:left;"
|+'''Universal dynamic PET board โ€” electrolytics and tantalums'''
! Ref !! Value !! Type !! Commodore part no.
|-
| '''C1, C16, C17, C23, C24''' || 10 ยตF 25 V || Electrolytic, '''low-leakage''' || 900109-03
|-
| '''C2''' || 4700 ยตF 16 V || Electrolytic || 900100-44
|-
| '''C5''' || 4700 ยตF 25 V || Electrolytic || 900100-45
|-
| '''C7, C11''' || 47 ยตF 16 V || Electrolytic || 900101-37
|-
| C6, C51 || 1 ยตF 35 V || '''Tantalum''' โ€” fit a tantalum || 900402-13
|}
ย 
Three things worth noting before ordering:
ย 
* '''C1, C16, C17, C23 and C24 are specified low-leakage parts''', not ordinary electrolytics.
* '''C2 and C5 are the same capacitance at different voltage ratings''' and are not interchangeable in the safe direction. C5 is the 25 V part.
* Everything else in the C1โ€“C97 range on this board is a ceramic, a mica or a tantalum, and ceramics do not age the way aluminium electrolytics do.<ref name="tm4k" />
ย 
The bulk filter, C1 in the supply chassis, is a separate 23,000 ยตF can and is the part under the most ripple stress in the machine.
ย 
Symptoms that justify pulling the boards:
ย 
* Vertical hold or geometry drifting on the CRT
* Unstable start-up, flickering or rolling picture
* Random freezes or garbled text
* Random freezes or garbled text
* Any brown crust or verdigris around a capacitor bung


=== Recommended Areas to Recap ===
See [[Capacitor Failure Symptoms]].
* Mainboard decoupling capacitors (especially around RAM chips)
* CRT analog section (for power filtering)
* Power supply (main filter caps, axial types)
ย 
Refer to the [[Commodore PET 4000 Series Capacitor Replacement Guide]] for a full list.


== ๐ŸŽน Keyboard Maintenance ==
== Keyboard ==


The PET 4000 Series typically features a full-travel keyboard, which may suffer from key bounce, non-responsive keys, and deterioration.
The 4000-series machines use a full-travel keyboard. Bounce, dead keys and whole dead rows are the usual complaints.


=== Cleaning Procedure ===
* Remove the keyboard from the chassis and photograph the keycap layout before taking anything apart.
* Remove keyboard from the chassis.
* Clean the contact pads on the PCB with isopropyl alcohol.
* Disassemble keycaps and springs (carefully photograph layout).
* Inspect for lifted traces and corroded vias, and check the connector at both ends โ€” a whole dead row or column is far more often a connector or a broken trace than it is a bad key.
* Clean contact pads on the PCB using isopropyl alcohol.
* Conductive paint will restore a worn pad but does not last as well as the original plating; treat it as a last resort.
* Polish carbon contact domes if applicable.
* Inspect for lifted traces or oxidized vias.


=== Repair Tips ===
== Sockets ==
* Use conductive paint to restore worn-out pads.
* Replace deteriorated foam/copper domes with modern equivalents (keyboard repair kits exist).
* For permanently dead rows/columns, trace the keyboard matrix and check solder joints or connector oxidation.


== ๐Ÿ“บ CRT Maintenance ==
Commodore's board drawing lists 24-pin and 40-pin low-profile IC sockets and a 14-pin socket, so most of the large devices are socketed.<ref name="tm4k" /> Sockets of this age lose contact pressure: remove suspect devices with a proper puller, clean the pins and the socket, and reseat firmly. Replace failed sockets with turned-pin types.


The CRT in the PET 4000 Series may experience issues over time.
== CRT ==


=== Common Issues ===
* Cold solder joints on the neck board and the deflection board are common.
* Cold solder joints on CRT neck board or deflection board.
* Brightness and focus drift; both have trimpots on the display board.
* CRT brightness/focus may drift โ€” use internal trimpots for focus and brightness (accessible on deflection board).
* If the tube does not light at all, the fault is in the heater supply or the EHT section, not the logic board.
* If the CRT fails to light up:
** Check filament voltage
** Verify flyback transformer and HV section


**Safety Warning:** CRT displays contain high voltage and can retain a charge even when powered off. Proper discharge procedures must be followed before servicing.
The technical manual carries the full drawing set for both the 9-inch and the 12-inch display, starting at drawing 321450 for the 12-inch, including the PCB waveform photographs with the oscilloscope settings printed on the drawings.<ref name="tm4k" />


== ๐Ÿงช Diagnostics and Burn-In ==
'''The CRT retains a charge with the machine unplugged.''' Follow [[CRT Discharge Procedure]] before working near the tube.


=== Diagnostic Tools ===
== Diagnostics ==
* Use a PET tester ROM (e.g., dead test cartridge or test harness) for RAM and ROM diagnostics.
* Use a logic probe or oscilloscope to check clock (phi2) and reset behavior.


=== Burn-In Tips ===
* A PET diagnostic ROM or test harness will exercise RAM and ROM far faster than swapping chips.
* Leave PET running on test pattern for several hours to identify marginal components.
* A logic probe or scope on the ฯ•2 clock and the reset line separates "the CPU is not running" from "the CPU is running and the video is wrong" in seconds. '''Y1 on this board is 16 MHz.'''<ref name="tm4k" />
* Monitor voltage regulators for excessive heat.
* Running the machine for a few hours on a test pattern will surface marginal parts that pass a cold test. Watch the three regulators while it does.


== ๐Ÿ”ง Voltage Test Points ==
== Tools ==


Use a multimeter to check:
* ESD-safe driver set, chip puller, plastic spudger
* +5V at 6502 Vcc (Pin 8)
* Digital multimeter, CRT discharge tool
* +12V on cassette motor supply
* Isopropyl alcohol (99 %), contact cleaner, anti-static brush
* CRT filament voltage (typically ~6.3VAC)
* Fine-tip temperature-controlled soldering iron, braid or pump
* Mains side capacitors should not show leakage or bulging.
* ESR meter, logic probe or scope


== ๐Ÿงฐ Tools Youโ€™ll Need ==
See [[Recommended Tools]].
* ESD-safe screwdriver set
* Chip puller or spudger
* Isopropyl alcohol (99%)
* Contact cleaner (e.g., DeoxIT)
* Soldering iron with fine tip
* Capacitor tester (optional)
* Logic probe or oscilloscope (advanced)


== ๐Ÿ“Ž Related Pages ==
== Related pages ==
* [[Commodore PET 4000 Series]]
* [[Commodore PET 4000 Series Troubleshooting Guide]]
* [[Commodore PET 4000 Series Troubleshooting Guide]]
* [[Commodore PET 4000 Series Capacitor Replacement Guide]]
* [[Commodore PET 4000 Series Technical Manual]]
* [[Commodore PET 2001 General Maintenance]]
* [[CRT Discharge Procedure]]
* [[CRT Discharge Procedure]]
* [[Capacitor Failure Symptoms]]
== References ==
<references />


[[Category:Commodore Systems]]
[[Category:Commodore Systems]]
[[Category:Commodore Maintenance Guides]]
[[Category:Maintenance Guides]]

Latest revision as of 20:05, 23 September 2026

Commodore PET 4032 with the top panel lifted.

This page covers routine care of the Commodore PET 4000 Series: cleaning, supply checks, keyboard servicing, socket work and the CRT hazards. For fault-finding see Commodore PET 4000 Series Troubleshooting Guide.

Every electrical figure here is read off Commodore's own drawings in the PET 4000 Series Technical Manual, P/N 990438, hosted on this wiki.[1] Where Commodore gives no figure, none is given here.

This is the "universal dynamic PET" board, not the static board of the Commodore PET 2001. The rails differ, the regulators differ and the crystal differs. Do not carry figures between the two pages in either direction.

Before you start

[edit | edit source]
  • Mains voltage is on the primary side of T1 whenever the machine is plugged in.
  • C1 in the supply chassis is 23,000 ยตF.[1] That is a large amount of stored energy for a low-voltage rail. Bleed it through a resistor; do not short it with a screwdriver.
  • The CRT holds its anode charge long after power-off. Discharge it before working near the tube โ€” see CRT Discharge Procedure.

Regular cleaning

[edit | edit source]

Internal

[edit | edit source]
  • Disconnect from the mains and discharge the CRT before the top goes up.
  • The hinged chassis lifts to expose the logic board and the display.
  • Compressed air and an anti-static brush on the logic board, particularly under and around the ROM and RAM sockets, on the regulator heatsinks and around the CRT neck board.
  • Isopropyl alcohol (>90 %) on swabs for stubborn areas. Do not soak.

External

[edit | edit source]
  • Mild soap on a damp microfibre cloth for the painted steel case.
  • Glass cleaner sprayed onto a lint-free cloth, never onto the tube.
  • Do not rub the screen-surround legend; the print is fragile.

Power supply

[edit | edit source]
What is where
Assembly Contents Regulators
Supply chassis (drawing 8032051) Transformer T1, 23,000 ยตF filter C1, fuse F1 (1.6 A slow-blow, 125 V), rocker switch SW1 None
Logic board (drawing 8032090) Bridges CR2/CR4, diodes CR1/CR5/CR7, zeners VR5/VR6 VR1, VR2, VR4
Regulators and rails
Ref Device Rail Commodore part no.
VR4 LM323, TO-3 +5 V 901528-01
VR2 7812 +12 V, 1 A 901528-04
VR1 7905 โˆ’5 V, 1.5 A 901527-03

The +5 V regulator is an LM323, not a 7805. It is a TO-3 5 A part, the same one Commodore used on the early Commodore VIC-20 board, and a 1 A TO-220 device is not a substitute for it.

There is a โˆ’5 V rail on this machine, from VR1. The PET 2001 has none, so rail lists do not transfer between the two.

What to inspect

[edit | edit source]
  • Transformer and the rectifier area for heat stress, discoloured board and corrosion.
  • Solder joints at VR1, VR2 and VR4 and at bridges CR2 and CR4. These are thermally cycled, heavy-current joints and a cracked one produces an intermittent that mimics a failing chip.
  • The regulator heatsinks and the thermal compound under them. Commodore fits heatsinks and thermal compound to this board because these parts run hot.[1]
  • Commodore's supply-chassis drawing names no mains-rated X-class or Y-class suppression capacitor โ€” the chassis holds one capacitor, C1, and it is the 23,000 ยตF filter on the low-voltage side.[1] The "replace the RIFAs on sight" advice that applies to many European machines of this era is not supported by Commodore's documentation for this one. If your machine has such a part fitted, deal with it on its merits; do not go hunting for one on the strength of a generic warning.

Voltage test points

[edit | edit source]
Where to measure
Rail Where Note
+5 V VR4 output, or 6502 pin 8 Pins 1 and 21 are ground; pin 40 is RESET, not a supply pin
+12 V VR2 output 1 A device
โˆ’5 V VR1 output 1.5 A device. Dynamic RAM of this generation needs it
Unregulated Across C1 in the supply chassis 23,000 ยตF. Treat with respect

A rail more than a few per cent off its nominal means the regulator, its heatsinking or the filtering ahead of it. Commodore publishes no tolerance band of its own for these rails, so none is quoted here; work to the regulators' own datasheet figures.

Capacitors

[edit | edit source]

Commodore's list for the logic board. This is the whole electrolytic complement.[1]

Universal dynamic PET board โ€” electrolytics and tantalums
Ref Value Type Commodore part no.
C1, C16, C17, C23, C24 10 ยตF 25 V Electrolytic, low-leakage 900109-03
C2 4700 ยตF 16 V Electrolytic 900100-44
C5 4700 ยตF 25 V Electrolytic 900100-45
C7, C11 47 ยตF 16 V Electrolytic 900101-37
C6, C51 1 ยตF 35 V Tantalum โ€” fit a tantalum 900402-13

Three things worth noting before ordering:

  • C1, C16, C17, C23 and C24 are specified low-leakage parts, not ordinary electrolytics.
  • C2 and C5 are the same capacitance at different voltage ratings and are not interchangeable in the safe direction. C5 is the 25 V part.
  • Everything else in the C1โ€“C97 range on this board is a ceramic, a mica or a tantalum, and ceramics do not age the way aluminium electrolytics do.[1]

The bulk filter, C1 in the supply chassis, is a separate 23,000 ยตF can and is the part under the most ripple stress in the machine.

Symptoms that justify pulling the boards:

  • Vertical hold or geometry drifting on the CRT
  • Unstable start-up, flickering or rolling picture
  • Random freezes or garbled text
  • Any brown crust or verdigris around a capacitor bung

See Capacitor Failure Symptoms.

Keyboard

[edit | edit source]

The 4000-series machines use a full-travel keyboard. Bounce, dead keys and whole dead rows are the usual complaints.

  • Remove the keyboard from the chassis and photograph the keycap layout before taking anything apart.
  • Clean the contact pads on the PCB with isopropyl alcohol.
  • Inspect for lifted traces and corroded vias, and check the connector at both ends โ€” a whole dead row or column is far more often a connector or a broken trace than it is a bad key.
  • Conductive paint will restore a worn pad but does not last as well as the original plating; treat it as a last resort.

Sockets

[edit | edit source]

Commodore's board drawing lists 24-pin and 40-pin low-profile IC sockets and a 14-pin socket, so most of the large devices are socketed.[1] Sockets of this age lose contact pressure: remove suspect devices with a proper puller, clean the pins and the socket, and reseat firmly. Replace failed sockets with turned-pin types.

  • Cold solder joints on the neck board and the deflection board are common.
  • Brightness and focus drift; both have trimpots on the display board.
  • If the tube does not light at all, the fault is in the heater supply or the EHT section, not the logic board.

The technical manual carries the full drawing set for both the 9-inch and the 12-inch display, starting at drawing 321450 for the 12-inch, including the PCB waveform photographs with the oscilloscope settings printed on the drawings.[1]

The CRT retains a charge with the machine unplugged. Follow CRT Discharge Procedure before working near the tube.

Diagnostics

[edit | edit source]
  • A PET diagnostic ROM or test harness will exercise RAM and ROM far faster than swapping chips.
  • A logic probe or scope on the ฯ•2 clock and the reset line separates "the CPU is not running" from "the CPU is running and the video is wrong" in seconds. Y1 on this board is 16 MHz.[1]
  • Running the machine for a few hours on a test pattern will surface marginal parts that pass a cold test. Watch the three regulators while it does.

Tools

[edit | edit source]
  • ESD-safe driver set, chip puller, plastic spudger
  • Digital multimeter, CRT discharge tool
  • Isopropyl alcohol (99 %), contact cleaner, anti-static brush
  • Fine-tip temperature-controlled soldering iron, braid or pump
  • ESR meter, logic probe or scope

See Recommended Tools.

[edit | edit source]

References

[edit | edit source]
  1. โ†‘ 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 Commodore Business Machines, PET 4000 Series Technical Manual, P/N 990438, for models 4016 and 4032, hosted at Commodore PET 4000 Series Technical Manual. Drawing 8032090 Rev H, "PCB ASSY โ€“ UNIV. DYNAMIC PET": sheet 3 gives the board capacitors by reference designator and Commodore part number (C1/C16/C17/C23/C24 10 ยตF 25 V low-leakage 900109-03; C2 4700 ยตF 16 V 900100-44; C5 4700 ยตF 25 V 900100-45; C7/C11 47 ยตF 16 V 900101-37; C6/C51 1 ยตF 35 V tantalum 900402-13; C3/C4 0.022 ยตF ceramic; C52/C60/C61 0.01 ยตF ceramic; C74โ€“C86 and C88 47 pF ceramic; C92 220 pF ceramic; C97 82 pF dipped mica) together with transistors Q1 and Q2 (TIP29) and the piezo-acoustic transducer MT1; sheet 4 gives the diodes CR1/CR5/CR7 (1N4005), bridges CR2 and CR4 (4 A/50 V), CR3 (1N5402), the three voltage regulators โ€” VR1 a 7905 at โˆ’5 V/1.5 A (901527-03), VR2 a 7812 at +12 V/1 A (901528-04) and VR4 an LM323 in TO-3 (901528-01) โ€” the 7.5 V zeners VR5 and VR6, the 16 MHz crystal Y1 (900556-02), the socket and header list, the 2.2 ยตH inductors L1 and L2, and the heatsinks. Drawing 8032051 Rev E, "Power Supply Assy, 8032": the supply chassis is transformer T1 (320902-01) on universal power chassis 8032043-02, filter capacitor C1 of 23,000 ยตF (900102-01), the dynamic PET power harness 320289-01, fuse F1 at 125 V slow-blow 1.6 A (903557-04), fuse holder XF1 and rocker switch SW1 โ€” with no voltage regulator and no mains-rated suppression capacitor listed. Drawings 321450 onward cover the 12-inch and 9-inch CRT displays.