Macintosh Classic/ Classic II/Performa 200 Service Source
The Macintosh Classic/Classic II/Performa 200 volume of Apple's Service Source covers all three of those machines in one manual. The PDF was distilled on 22 January 1996.
What it settles
- Battery: replace below 3.0 V. Apple's Battery Verification procedure says to set the voltmeter to the 10 V DC scale, measure across the cell, and "if the battery voltage is below 3.0 volts, replace the battery". This is the figure for the Classic family; the SE and SE/30 threshold is 2.8 V and should not be transplanted here. The cell is lithium, and Apple's warning is explicit: handled or discarded improperly it can explode.
- Battery verification requires the logic board out. Apple's "before you begin" is remove the cover, discharge the CRT, remove the logic board. It is not a measurement you take with the machine assembled.
- Processors: Classic is a Motorola 68000 at 7.8336 MHz with 256-byte instruction and data caches; Classic II and Performa 200 are a 68030 at 16 MHz, also with 256-byte caches.
- Memory: Classic 1 MB expandable to 4 MB (120 ns or faster SIMMs); Classic II and Performa 200 2 MB expandable to 10 MB (120 ns or faster). ROM 512K; PRAM 256 bytes. The Classic's memory expansion is a 44-pin cache connector carrying 256K x 4-bit DRAMs and two further SIMM sockets.
- Electrical: line voltage 100-120 V AC, 47-63 Hz single phase. No 220-240 V figure is printed in this manual, so nothing in it should be applied to a 240 V analogue board.
- Physical: 13.2 in (33.6 cm) H x 9.7 in (24.6 cm) W x 11.2 in (28.5 cm) D; 16-17.1 lb (7.3-7.8 kg) without an internal hard drive.
Contents
- Basics - Overview
- Specifications - Processor, Memory, Disk Storage, I/O Interfaces, I/O Devices, Sound and Video, Electrical, Physical (pdf pp. 5-12)
- Troubleshooting - General, symptom charts for Video, Floppy Drives, Hard Drives, Peripheral and Miscellaneous (pdf pp. 14-28)
- Take Apart - Cover, Power/Sweep Board, Logic Board, Hard Drive, Floppy Drive, Fan, CRT, Chassis and Front Bezel, Fuse (pdf pp. 30-66)
- Upgrades - Memory Expansion Board, Memory Upgrade, Classic II Upgrade (pdf pp. 68-79)
- Additional Procedures - Battery Verification, Battery Replacement (pdf pp. 81-88)
- Adjustments - Light Meter Setup, Video, Yoke (pdf pp. 90 onwards)
- Exploded View
What this manual does not contain
No parts list, no schematic and no component values - there is no analogue-board capacitor table in this document, and any such table elsewhere that cites this manual is not sourced from it. There is no voltage adjustment procedure: the Adjustments chapter covers light-meter setup, video and yoke only, so the "+5 V 4.85-5.15 V / +12 V 11.90-12.75 V" figures from the Macintosh 128K/512K and Plus manuals have no counterpart here and do not apply to the Classic family. The Fuse take-apart names the position but prints no rating. The Electrical specification covers the 100-120 V machine only.
This copy is 115 pages. A second, slightly shorter copy is on this wiki as Macintosh Classic / Classic II Service Source (113 pages). The two are the same manual; the difference is in the Adjustments chapter's Light Meter Setup topic, which in this copy covers three light meter models (R77, L-248 and 246) and in the shorter copy covers two (Switch Models L-248 and 246). This is the fuller copy.
Pages that cite this document
- Macintosh Classic II, Macintosh Performa 200, Macintosh Classic
- Macintosh Classic / Classic II General Maintenance and Macintosh Classic / Classic II Troubleshooting - the 3.0 V battery threshold and the absence of any voltage adjustment.
- Macintosh Performa 200 General Maintenance, Macintosh Performa 200 Troubleshooting
Warning: these machines contain a high-vacuum picture tube and a live analogue/power-sweep board. Follow CRT Discharge Procedure before working inside one; Apple's own Take Apart chapter opens with the same warning.
Download: Classic ii.performa 200.pdf