Sega Dreamcast Capacitor Replacement Guide
A Sega Dreamcast holds its electrolytics in four places: the logic board, the power supply, the GD-ROM optical board and the small controller-interface board. All four have their own designators, all four vary by revision, and none of them is interchangeable with another.

No Sega Dreamcast service manual carrying a parts list is hosted on this wiki — the Sega Dreamcast VA0 Schematics here are schematics and diagrams only, with no bill of materials. Every value on this page therefore comes from console5's board-reads, and is cited as the secondary source it is.[1]
How the Dreamcast is numbered
editOn the logic board, aluminium electrolytics carry CE designators — CE103, CE301 to CE310, CE401, CE403, CE503, CE601, and the CE7xx and CE8xx positions on later boards.[1] Plain C numbers on a Dreamcast belong to the GD-ROM board or the power supply, which use their own sequences.
A logic-board capacitor list built out of consecutive plain C designators is therefore not describing this machine, whatever the values say.
Identify the board
edit| Revision | Notes |
|---|---|
| VA0 | Earliest logic board. No CE103, CE302, CE307 or CE601 fitted |
| VA1 | 837-13778 / 171-7965C. The most common board |
| VA2.1 | Adds the CE7xx and CE8xx positions and drops CE503 |
All Dreamcast consoles have an internal, mains-powered supply. There is no revision that takes an external power brick: console5 lists internal supply boards for both 110 V markets (171-7874A, -7874A-X1, -7874B, -7874B-X2, 171-7962A, -7962A-X1, 171-7970A, -7970A-X2) and 220–240 V markets (171-7960A, PWR UNIT PANA EU V01, ETXSE239E2C).[1] Any guide that says a Dreamcast revision uses an external PSU and needs no internal supply work is wrong, and following it would leave the most failure-prone board in the machine untouched.
Logic boards
edit| Value | Designators |
|---|---|
| 10 µF 16 V | CE301, CE310 |
| 10 µF 10 V, bipolar | CE303, CE304 |
| 22 µF 6.3 V | CE305, CE306 |
| 47 µF 16 V | CE308 |
| 4.7 µF 35 V (25 V acceptable) | CE309 |
| 220 µF 6.3 V | CE401 |
| 100 µF 6.3 V | CE403 |
| 47 µF 25 V | CE503 |
| Value | Designators |
|---|---|
| 47 µF 16 V | CE103, CE308 |
| 10 µF 16 V | CE301, CE302, CE310 |
| 10 µF 10 V, bipolar | CE303, CE304 |
| 22 µF 6.3 V | CE305, CE306 |
| 100 µF 16 V | CE307 |
| 4.7 µF 35 V (25 V acceptable) | CE309 |
| 220 µF 6.3 V | CE401 |
| 100 µF 6.3 V | CE403 |
| 47 µF 25 V | CE503 |
| 47 µF 6.3 V | CE601 |
| Value | Designators |
|---|---|
| 47 µF 16 V | CE103, CE308 |
| 10 µF 16 V | CE301, CE302, CE310 |
| 10 µF 10 V, bipolar | CE303, CE304 |
| 22 µF 6.3 V | CE305, CE306 |
| 100 µF 16 V | CE307, CE801, CE802, CE805, CE808 |
| 4.7 µF 35 V (25 V acceptable) | CE309 |
| 220 µF 6.3 V | CE401 |
| 100 µF 6.3 V | CE403, CE701, CE807 |
| 47 µF 6.3 V | CE601, CE803, CE804, CE806 |
| 47 µF 25 V | CE809 |
CE303 and CE304 are bipolar parts. They are non-polarised by design and must be replaced with bipolar capacitors, not with ordinary polarised electrolytics fitted "the right way round".[1]
The controller-interface and battery board carries one capacitor, CE1, 47 µF 16 V, on every revision.[1]
GD-ROM optical boards
edit| Board | Value | Designators |
|---|---|---|
| XU937 | 47 µF 6.3 V | C2 |
| 100 µF 6.3 V | C3, C10, C14, C17, C61 | |
| 100 µF 16 V | C20, C122 | |
| XV779 / KS-7S | 100 µF 6.3 V | C10, C14, C17, C61, C511 |
| 100 µF 16 V | C20, C509 | |
| 47 µF 6.3 V | C127, C203, C205 | |
| 171-8129A | 100 µF 6.3 V | C10, C14, C17, C61, C513, C520 |
| 100 µF 16 V | C20, C509 | |
| 47 µF 6.3 V | C127, C203, C205 |
On the XV779 board, C510 is an empty position.[1]
The other common GD-ROM fault is mechanical rather than electrical: the plastic spur gears in the optical drive strip, which stops the sled moving. console5 hosts an installation guide for replacement gears.[1] A drive that spins a disc but never reads it is worth checking for a stripped gear before the laser is condemned.
Power supplies
editThe supply board is the one board in a Dreamcast that carries mains potential, and its bulk capacitor stores charge after the lead is pulled: 100 µF at 200 V on 110 V units, 47 µF at 400 V on 220–240 V units.[1] Unplug the console, measure across that capacitor and discharge it through a resistor before working. Done that way this is ordinary repair work, and on a machine of this age the supply is usually the board most in need of it.
| Board | Value | Designators |
|---|---|---|
| 171-7874A, -7874A-X1, -7874B (110 V; usually paired with VA0) | 100 µF 200 V | C3 |
| 47 µF 35 V | C10 | |
| 1000 µF 25 V | C13 | |
| 220 µF 25 V | C16 | |
| 2200 µF 10 V | C17, C21 | |
| 1500 µF 6.3 V / 470 µF 10 V | C20 / C22 | |
| 171-7874B-X2, 171-7962A, -7962A-X1, 171-7970A, -7970A-X2 (110 V; usually VA1 and VA2.1) | 100 µF 200 V | C3 |
| 47 µF 35 V | C10 | |
| 470 µF 35 V | C52 | |
| 470 µF 16 V | C53 | |
| 2200 µF 10 V | C54 | |
| 470 µF 10 V | C56 | |
| 3300 µF 10 V / 1000 µF 10 V | C58 / C59 | |
| 171-7960A, PWR UNIT PANA EU V01, ETXSE239E2C (220–240 V) | 47 µF 400 V | C006 |
| 1800 µF 16 V | C101, C201 | |
| 1200 µF 10 V | C103 | |
| 470 µF 16 V | C204 | |
| 1000 µF 25 V (35 V on some units) | C301, C302 |
The switching controller on the supply is an FA5317.[1]
IC map, VA1 171-7965C
editUseful when tracing a rail back to what it feeds.[1]
| Designator | Device | Function |
|---|---|---|
| IC101 | SH-4 | Main CPU |
| IC102, IC103 | 64 Mbit SDRAM | Main memory |
| IC104 | PQ07VZ1H2Z | Series regulator |
| IC106 | RN5RG25A | CMOS regulator — the fitted part is tied to the Holly variant: 313-5612 with a 315-6201 or 315-6225, 313-5553 with a 315-6226 |
| IC201 | 315-6201 / 315-6225 / 315-6226 | Holly graphics engine |
| IC202–IC205 | 16 Mbit SDRAM | Video memory |
| IC206 | RN5VD27A | Power-on reset |
| IC301 | 315-6119 / 315-6232 | AICA sound processor |
| IC302 | 16 Mbit SDRAM | Sound memory |
| IC303 | PCM1725 | Audio DAC |
| IC305 | W129A | Clock generator |
| IC401 | BU1426KS | RGB encoder |
| IC501 | MPR-21931 | Boot ROM |
Doing the work
edit- Unplug the console. Remove the modem, then the case screws, then the top shell.
- Take the power supply out and discharge its bulk capacitor before anything else.
- Note the orientation of every connector before unplugging it.
- Lift the surface-mount parts on the logic board with hot air or two irons, never by levering.
- Clean each footprint with isopropyl alcohol and inspect under magnification — see Battery Explosion, Capacitor or Corrosion Damage if anything has leaked.
- Fit 105 °C low-ESR parts at the original values, bipolar where the original was bipolar, stripe to the negative end.
- Reassemble and test before closing the case.
General tooling is on Recommended Tools; what each failure mode looks like is on Capacitor Failure Symptoms.
After the recap
editThis wiki has not found a source that publishes the Dreamcast's rail voltages and tolerances — Sega's hosted schematics do not tabulate them — so no voltage table is given here rather than a guessed one. What can be checked without one:
- the console powers up and reaches the boot animation with no disc;
- audio is clean on both channels, which exercises the AICA, the PCM1725 and the capacitors around them;
- video is stable and free of noise;
- the GD-ROM spins up, the sled moves smoothly and a game disc loads;
- the machine still works after twenty minutes warm, which is when a marginal supply shows itself.
Related pages
editReferences
edit- ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 console5 TechWiki, Dreamcast, https://wiki.console5.com/wiki/Dreamcast . Secondary source — capacitor lists read off real boards for the VA0, VA1 and VA2.1 logic boards, the GD-ROM optical boards, the controller interface board and the power supply units, together with the IC map for the VA1 171-7965C board. No Sega Dreamcast service manual with a parts list is hosted on this wiki, so this is the only component-level source cited here.