Tuning Server Performance and Adding Internal Hard Drives for the Apple Workgroup Server 95 is a 1994 Apple manual for the Apple Workgroup Server 95, written to supplement the server's A/UX and AppleShare Pro manuals. This scan has 48 PDF pages; the printed pages run to 35 plus the front matter, and printed page n of the appendix is PDF page n + 8.[1]

Contents

[edit | edit source]

Printed page numbers, from the contents page.

  • Preface: About This Document (v)
  • 1 Measuring Server Performance (1)
  • 2 Allocating RAM for Best Performance (7): the A/UX buffer cache, the AppleShare Pro caches, Macintosh virtual memory, paging
  • 3 Optimizing Performance When Running AppleShare Pro and NFS (17)
  • 4 Preparing Your Server for Another Service (21): the config_server script
  • Appendix: Adding Internal Drives (23): before you start (24), installation procedure (24-33)
  • Index (35)

What it settles

[edit | edit source]
  • The AWS 95 has built-in SCSI termination; drives added to it must have their resistor packs removed (printed pp. 24, 29).
  • Fill the drive slots in letter order and use slot E last, for heat reasons (p. 30).
  • Five 2 GB drives lower the maximum ambient operating temperature to 35 °C; four or fewer drives allow 40 °C (p. 23).
  • SCSI IDs 1, 4, 5 and 6 are always available for hard disks on the PDS card's internal bus (p. 31).